6.2 Switch on drive

Immediately (max. 10 seconds on 50 Hz resp.
max. 7 seconds on 60 Hz currency feed) after
reaching normal operating speed open discharge
valve adjust the required operating point. The
pumping data shown at the type plate resp. in the
data sheet and / or the order confirmation must be
met. Every change is only permitted after talking
with the manufacturer!
Operation with closed valve in the suction and /
or discharge piping is not permitted.
On starting-up without back-pressure, the back-
pressure must be produced through throttling at
the discharge side. After reaching full back-
pressure open valve
In order that the shaft sealing can be monitored
and maintained unhindered, no protection cover
is provided in this area. Therefore special
attention is required when pump is working (no
long hair, loose clothes, a.s.o.).
Packing: Packing need leakage for trouble free
function (drop wise outlet of pumped medium).
Adjust ample leakage in the beginning. Reduce
that slowly during the first operating hours by
continuously fastening of gland (see position "69"
and "M3" in sectional drawing) when pump is
running. Assume 60-100 drops / minute as
approx. value.
The leakage must flow out liquid in any case (not
vaporous).
Packing that run dry will harden and then
destroy the shaft sleeve and/or the shaft.
Mechanical seals: Mech. seals don't need to be
maintained and are almost free of leakage.
If pump does not reach attended head or if
atypical sounds or vibrations do occur:
Switch off pump (see chapter 6.7) and seek for
causes (see chapter 10).

6.3 Restarting

Basically, the same procedure should be followed as
for starting up for the first time. However, there is no
need to check the direction of rotation and the
accessibility of the pump unit.
The pump should only be automatically restarted if it
has been made sure that the pump has remained
filled whilst stand by.
Be particularly careful not to touch hot machine
parts and when working in the unprotected shaft
seal
area.
Remember
controlled systems may switch themselves on
suddenly at any time. Suitable warning signs
should be affixed.
MP 100-english
Article No 771074011
that
automatically
page 89
Model MP, MPA, MPAI

6.4 Limits of Operation

The operating limits of the pump / unit regarding
pressure, temperature, performance and speed
are shown in the data sheet and / or order
confirmation and must be observed under any
circumstances!
Do not exceed the output given on the motor
name plate.
Avoid
sudden
(temperature shocks).
The pump and motor should run evenly and
without vibrations; check at least once a week.
6.4.1 Flow min. / max.
If no other data are given in the curves or data sheets,
the following is valid:
Q
= 0,1 x Q
for for short time operation
min
BEP
Q
= 0,3 x Q
for continuous operation
min
BEP
Q
= 1,2 x Q
for continuous operation *)
max
BEP
Q
= Flow in efficiency optimum
BEP
*) on condition that NPSH
facility
6.4.2 Abrasive Media
On pumping liquids with abrasive components
an increased wear at hydraulic and shaft sealing
must be expected. The intervals of inspection
should be reduced compared to the usual
times.

6.4.3 Permitted number of starts

With electric motors, the permitted number of starts is
given in the attached motor operating instructions.
If no values for the switching frequency are given in
the motor operating manual, the values according to
Diagram 7 apply.
100,0
10,0
1,0
1
10
Motor power [kW]
If two different figures are given, the lower figure is
valid.
changes
in
temperature
> (NPSH
+ 0,5 m)
pump
100
Diagram 7
Revision 02
Issue 01/2007
1000

Publicité

Table des Matières
loading

Table des Matières