Noise Levels - ITT MP Série Instructions De Montage, De Service Et De Maintenance

Table des Matières

Publicité

Installation, Operating and Maintenance Instruction
12.6.3 Bearing dimensions of the motors
frame size
DPIG 56
DPIG 63
DPIH 71
DPIH 80
DPIH 90
IMB3
DPIH 90
IMV1
DPIG 100
IMB3
DPIG 100
IMV1
DPIG 112
DPIG 132
DPIG 160
DPIG 180
DPIG 200
DPIG 225
2DPIG 225
DPIG 250
2DPIG 250
DPIG 280
2DPIG 280
12.6.4 Quantity of lubrication (g) according table
Frame
Bearing
Regreasing
size
type
DPIG 315 6315 C3
DPIG 315 6318 C3
SEE 315 6315 C3
6320 C3
SEE 315
6318 C3
DPIG 355 6317 C3
DPIG 355 6322 C3
SEE 355 6217 C3
SEE 355 6222 C3
Regreasing with grease nipples - while the machine is
running.
The table is prepared for horizontally mounted
machines. Lubrication intervals for vertical machines
are half of the above values.
The grease amount in the table given is used if small
quantities of fresh grease are replaced at regular
intervals as above.
As an alternative, when the machine is fitted with
grease escape valves, fresh grease may be pressed
into the bearings until the old grease is totally
replaced.
The table values are based on 80° C bearing
temperature. The values should be halved for every
15° C increase in bearing temperature.
If the maximum bearing temperature is 70° C, the table
values may be doubled.
The maximum operating temperature of the
grease and bearings must not be exceeded.
MP 100-english
Article No 771074011
bearing type
6201 ZZ
6202 2RS
6203 2RS
6204 2RS
6205 ZZ C3
6205 ZZ C3
6305 ZZ C3
6206 ZZ C3
6206 ZZ C3
6306 ZZ C3
6306 ZZ C3
6308 ZZ C3
6309 ZZ C3
6311 ZZ C3
6212 ZZ C3
6213 ZZ C3
6313 ZZ C3
6215 ZZ C3
6315 ZZ C3
6215 ZZ C3
6315 ZZ C3
Change of
Remarks
grease
30
170
2 polig
40
260
4 - 8 polig
30
170
2 polig
50
300
4 - 8 polig
40
260
30
300
2 polig
65
585
4 - 8 polig
21
460
2 polig
38
460
4 - 8 polig
page 106
Model MP, MPA, MPAI
Higher speed operation, e.g. frequency converter
applications, or slower speed with heavy load will
require shortened lubrication intervals.
Typically a doubling of speed will require a reduction of
lubrication intervals to approx. 40% of values tabulated
above.
Suitability of bearings for high speed operation must
also be checked.
Lubricants:
When regreasing, use only special ball bearing grease
with the following properties:
good quality lithium base or lithium complex
grease
base oil viscosity 100-140 cST at 40° C
consistency NLGI grade 2 or 3
temperature range -30° C - +120° C, continuously.
Greases with the correct properties are available from
all the major lubricant manufacturers.
If the make of grease is changed and compatibility is
uncertain, lubricate several times at short intervals in
order to displace the old grease.
Highly loaded and/or slowly rotating bearings require
EPgrease.
If lubrication intervals are short due to bearing
temperatures of 80° C or above, use high temperature
greases which normally permit approximately 15 K
higher bearing temperatures.
If the ambient temperature is below -25° C consult the
manufacturer regarding the possible use of low
temperature grease.
NOTE
For
high
speed
machines
machines), check that the fn factor of the grease is
sufficiently high.
fn = Dm x n
Dm = average bearing diameter (mm)
n = rotational speed (r/min)
Many greases can cause skin irritation and eye
inflammation.
Follow all safety precautions specified by the
manufacturer.
12.6.5 Spare parts
When ordering spare parts, the full type designation
and product code as stated on the rating plate must be
specified.
If the machine is stamped with a serial manufacturing
number, this should also be given.

12.6.6 Noise levels

Smaller machines have a sound pressure level which
does not exceed 70 dB(A).
The following table indicates the sound pressure level
of all motor types of the frame sizes 56 - 355, 2 / 4 / 6 /
8 pole.
(e.g.
larger
2-pole
Revision 02
Issue 01/2007

Publicité

Table des Matières
loading

Table des Matières