Fluke Thermalert 4.0 Manuel Utilisateur page 103

Table des Matières

Publicité

Thermalert
®
4.0
Manuel utilisateur, Rev. 2.0, oct. 2019
COMMAND LIST
Description
Laser control
FTC3 function selection:
Trigger / Hold / Laser
control
Analog output mode
selection
Lower threshold value for
Relay function
Main firmware revision
Analog Firmware revision
Upper threshold value for
Relay function
Trigger status
Device identification (model
name)
Device serial number
Advanced hold - hysteresis
temperature value
Amb count + IR ADC count
value
PSa value + Energy value
106
1.800.561.8187
Char Value Format Poll
Burst Set Legal values
XL
X
XN
X
XO
n
XP
nnnn.n
XR
nn.nn.nnnn
XRA
nn.nn.nnnn
XS
nnnn.n
XT
n
XU
XXXXXXXXXX
X
XV
nnnnnnnnn
XY
nnnn.n
YA
nnnnn#nnnnnn √
YB
nnnnnn#nnnnn
n
www.
Factory default 2-W 6-W 12-W 4-W
0 = OFF;
0
1 = ON;
H = overheat(OFF);
N = no laser built in
N = no function;
N
T = trigger;
H = hold;
L = laser
0 = 0-20mA;
9
4 = 4-20mA;
5 = TCJ (only for 6-wire);
6 = TCK(only for 6-wire);
9 = mV
Lower-limit of temperature
Lower-limit of
range ~ (Upper threshold
temperature
value for Relay function - 2 *
range
Deadband).
In current unit (°C/°F)
Examples:
6/12W: 01.01.1111
Ethernet, EtherNet/IP:
01.01.1111E
PROFINET: 01.01.1111P
e.g. 01.01.1111
(Lower threshold value for
Upper-limit of
Relay function + 2 *
temperature
Deadband) ~ Upper-limit of
range
temperature range.
In current unit (°C/°F)
0 = inactive;
0
1 = active
e.g. STRLTH5SFCW
e.g. 123456789
-100.0 ~ 100.0°C / -180.0 ~
0000.0
180.0°F
In current unit (°C/°F)
information@itm.com
.com