l) Power measurement (only for VC940)
With this measurement function, you can perform power measurements on devices with two-prong
Schuko-type (grounded) or Euro plugs quickly and easily using the supplied jack adapter.
The measuring range is 0–2500 W.
Proceed as follows to measure the power:
(A)
W
(B)
V
Ω
Hz
10A MAX
mAμA
COM
(C)
Switch the consumer on. The real power consumption of the consumer is shown on the main display
(12) in watts (W). The apparent power is shown on the right subdisplay in VA, and the power factor is
shown as "cos φ" on the left subdisplay.
Before you disconnect the consumer under test from the DMM, ensure that the consumer is off..
Never connect devices with power consumptions of > 2500 W to the DMM. The power
measurement adapter may only be connected to AC voltages (190 VAC to max. 250
VAC).
Measurement duration for power measurement: 0–1150 W: continuous measurement,
1150–2500 W: max. 10 seconds with 15-minute pause between measurements
10.

AUTO POWER OFF FUNCTION

In order to avoid unnecessary shortening of the operating life of the battery, an automatic switch-off
function has been implemented. The measuring device is factory-set to switch off after 10 minutes.
This time can be changed or the function deactivated in the setup menu. The measuring device can be
switched back on through pressing of the blue button or turning of the rotary switch.
If the Send function (transmission of current measured values to the interface) is active, the Auto Power
OFF function is deactivated.
52
Set the range selector switch (5) to "W".
Plug the supplied power measurement adapter (C) into the
DMM.
Insert the plug (A) from the power measurement adapter
into a Schuko-type outlet (max. 250 VAC).
Plug the consumer under test into the socket (B) on the
power measurement adapter. Ensure that the consumer
is off.
6.

MANIEMENT ET MISE EN SERVICE

Indications apparaissant sur l'écran et symboles
désigne la mesure de la valeur relative (= mesure de la valeur de référence)
AUTO
désigne la "Sélection automatique de la plage de mesure"
OL
désigne Overload = dépassement ; la plage de mesure a été dépassée
Symbole de remplacement des piles ; veuillez remplacer immédiatement les piles afi n
d'éviter toute erreur de mesure.
Symbole pour l'essai de diodes
Symbole pour le contrôleur acoustique de continuité
Symbole de la désactivation automatique (Auto-Power-OFF)
Symbole de l'éclairage d'affi chage activé
Affi chage de la valeur de mesure comme affi chage de niveau analogique
0
40
TRUE RMS Indicateur de la mesure effi cace vraie (AC ou couplé CC/CA)
AC
Grandeur alternative de la tension et du courant
DC
Grandeur continue de la tension et du courant
mV
Millivolt (exp.-3)
V
Volt (unité de tension électrique)
A
Ampère (unité de courant électrique)
mA
Milliampère (exp.-3)
μA
Microampère (exp.-6)
Hz
Hertz (unité de fréquence)
kHz
Kilohertz (exp.3)
MHz
Mégahertz (exp.6)
Ω
Ohm (unité de résistance électrique)
Kiloohm (exp.3)
Mégaohm (exp.6)
69