Resistance Measurement; Direct Current Measurement - VOLTCRAFT VC-12A Notice D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

c) Resistance measurement
Make sure that all parts of the circuit, switches and
components and other objects to be measured are dis-
connected from the voltage and discharged.
Proceed as follows to measure the resistance:
- With the rotary switch, select the measuring
range Ω x1K.
- Now perform the zero adjustment.
- Connect the black measuring line to the
COM socket (5) and the red measuring line
to the „+" measuring socket (6).
- Connect the two measuring tips and wait
until the pointer has stabilised. A value of
approx. 0 Ohm must be displayed. In case of
a deviation, adjust the pointer with the 0 Ohm calibration control (3) to
0 Ohm.
- Read off the measured value on the scale „Ω". Multiply the displayed
value by a factor of 1,000 to get the measured value e. g. 5 Ω (display)
x 1,000 = 5 x 1,000 = 5 kΩ (measured value).
- After completing the measurement, remove the measuring tips from
the measuring circuit and switch the multimeter off (rotary switch posi-
tion: „OFF").
d) Direct current measurement
Never exceed the max. permitted input values in the
respective measuring ranges.
Only make current measurements in circuits up to
max. of 250 V.
41