MAINTENANCE SPECIFICATIONS
Item
USA, Canada
IGNITION CONTROL SYSTEM
Thermo switch
On temperature
Off temperature
Over heat warning lamp
Rating
STARTING SYSTEM
Neutral switch
a
Length
(on)
b
Length
(off)
Fuse rating
STARTER MOTOR
Type
Output
Brush length
Wear limit
Commutator diameter
<Limit>
Commutator under cut
<Limit>
Clutch type
Pinion - ring gear gap
Rating
CHARGING SYSTEM
Lighting coil output peak voltage
@ cranking 1 (G - G)
@ cranking 2 (G - G)
@ 1,500 r/min (G - G)
@ 3,500 r/min (G - G)
Lighting coil resistance (1-coil)
Lighting coil resistance (2-coils)
Rectifier/regulator output peak
voltage
@ cranking 1 (R - B)
@ cranking 2 (R - B)
@ 1,500 r/min (R - B)
@ 3,500 r/min (R - B)
*Cranking 1: Open circuit voltage
Cranking 2: Loaded circuit voltage
Worldwide
Unit
°C (°F)
°C (°F)
V
mm (in)
mm (in)
V - A
kW
mm (in)
mm (in)
mm (in)
mm (in)
mm (in)
mm (in)
mm (in)
Sec.
V
V
V
V
Ω
Ω
V
V
V
V
E60HMHD
E60MH
18.5 - 19.5 (0.73 - 0.77)
19.5 - 20.5 (0.77 - 0.81)
Hitachi S108-97A
0.5-0.8 (0.02-0.03)
Over running
3.0 - 5.0 (0.12 - 0.20)
5.6 (no load)
5.6 (no load)
21.6 (no load)
47.2 (no load)
5.6 (no load)
5.6 (no load)
21.6 (no load)
47.2 (no load)
2-7
Model
E60HWHD
E60HWD
E60EH
—
87 (188.6)
67 (152.6)
1.7
12 - 10
0.6
12.5 (0.49)
9.0 (0.35)
30.0 (1.18)
29.0 (1.14)
0.2 (0.01)
30
0.41 - 0.50
1.31 - 1.60
E