Safety instructions

Repairs may only be carried out by an expert!
To avoid transportation damage, the device may only be
dispatched if the Truma Service Centre in Germany or the
respective authorised service partner has been consulted
beforehand.
The power supply must be disconnected from the mains (all
poles) before opening the housing.
The 230 V, T 6.3 A H-type (slow, IEC 127) device fuse can be
found on the electronic control unit in the device, and must
always be replaced with an identical fuse.
The device fuses and connection cables must only be re-
placed by experts.
Guarantee claims, warranty claims and acceptance of liability
will be ruled out in the event of the following:
– Modifications to the device (including accessories)
– Failure to use original Truma parts as replacement parts and
accessories
– Failure to follow the installation and operating instructions
This may also invalidate the device operating permit, which in
many countries also denotes cancellation of the vehicle oper-
ating permit.
The refrigerant circuit contains R 407C refrigerant and must
only be opened in the factory.
The air outlet and and the circulated air intake must not be
obstructed under any circumstances. This is essential in order
to ensure that your device operates correctly.
The openings beneath the floor of the vehicle must be kept
free of dirt and slush. These openings must not be within the
range of the wheel spray – fit splash guard if necessary.
If underbody protection is being applied to the floor of the
vehicle, all openings beneath the vehicle must be covered so
that the spray mist that is created does not penetrate the de-
vice and cause malfunctions. Remove covers again when the
work is complete.
In order to avoid damage to the compressor, no uphill or
downhill slopes with an incline of more than 8 % must be
driven on when the device is being operated while driving
(e.g. with generator or voltage converter).
Do not operate the device for long periods with the vehicle at
an angle, since the condensation that is produced may not be
able to run away and may penetrate the vehicle under unfa-
vourable circumstances.
In order to ensure that the equipment works properly and to
avoid damage, only power supply sources with a purely sinu-
soidal waveform (e.g. voltage converter, generator) and with-
out voltage peaks must be used.
When the floor of the vehicle is being cleaned, it must be
ensured that no water penetrates the openings in the base
of the device when spraying with a high-pressure cleaner, for
example.
For safety reasons the device must always be closed during
operation, since this is the only way to ensure that no injuries
are caused by moving parts. Then strap around the electronic
housing must not be removed.
14

Notes on using air conditioning systems

– The Saphir comfort RC air conditioning system is designed for
minimal power consumption. You should still check whether
the camp site has adequate fuse protection (min. 6 A) before
starting the equipment up.
– Park the vehicle in the shade if possible.
– Darkening with shutters and / or a canopy reduces the
amount of heat radiation.
– Clean your roof at regular intervals (dirty roofs heat up more
than clean roofs).
– The vehicle must be properly ventilated before starting the
equipment in order to remove accumulated warm air from
the vehicle.
– When aprons or the like are being fitted, please ensure that
adequate openings are present for dissipating the supply
air. The opening for the warm outgoing air should not be at
the inlet side.
– In order to obtain a healthy room climate, the difference
between the inside and outside temperatures should not be
too great. The recirculated air is cleaned and dried during
operation. A pleasant room climate is produced by drying
the moist air, even if the temperature difference is minimal.
– Keep all doors and windows closed when in cooling mode.
– Full ventilation power can only be achieved at all three
openings if three cold air ducts are connected.
– The blow-out duct (part no. 40040-32500) must not be used.
– When in heating mode, only use "high" fan level for rapid
heating. Set to "medium" or "low" during continuous
operation.