Aventics RTC-BV Notice D'instruction page 19

Vérins sans tige
Masquer les pouces Voir aussi pour RTC-BV:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
AVENTICS | RTC/CKP | R402003540–BAL–001–AG | English
Versions
Used at low and medium torques. Available with piston
size 16...80 mm.
Used at low and medium torques, where higher precision
than offered by RTC-BV is required. Available with piston
size 25, 32 and 40 mm.
Used where extra high precision is required. Available
with piston size 16...40 mm.
Used with high loads and torques (Heavy Duty) where
extra high precision is required. Available with piston size
16...63 mm.
RTC-RR Replacement series RMC
Used only to replace a series RMC cylinder. Not to be used
for new design. Similar to RTC-BV, but supplied with a
mounting surface on the slide according to cylinder
RMC-BV, and a mounting kit to replace RMC-BV. Available
with piston size 16...80 mm.
RTC-RI Replacement series 170
Used only to replace a series 170 cylinder. Not to be used
for new design. Similar to RTC-BV, but supplied with a
mounting surface on the slide according to cylinder series
170, and a mounting kit to replace series 170. Available
with piston size 16...80 mm.
RTC-BV
Basic Version
RTC-SB – Slide bearing
guide
RTC-CG
Compact Guide
RTC-HD
Heavy Duty
Used with high loads and torques. Available with piston
size 16, 25 and 32 mm.
CKP-CL camoLINE
Based on CKP, but with holes for centering rings
underneath for positioning. Available with piston size 16,
25 and 32 mm.
5
Assembly
The RTC and CKP cylinder is configured and dimensioned
for a particular application. Never modify the cylinders
compared to the original configuration.
O Check that the maximum values for operating
pressure, load, torque or speed stated in the technical
data are not exceeded.
Risk of injury or damage due to uncontrolled
movement of the slide!
If compressed air is connected while the cylinder is
being installed, this can lead to personal injury or
damage to the system.
O Make sure that the relevant part of the system is
depressurized while the cylinder is being installed.
O Make sure that the cylinder is completely installed
before connecting the compressed air supply.
O If the system has to be left unattended during
installation, make sure that the compressed air
supply cannot be reconnected.
Watch out for suspended loads!
Where the unit is installed vertically, a suspended load
may drop out of control if the compressed air is shut off.
This can lead to injuries.
O Always secure the area under a suspended load to
prevent people entering it.
Risk of heavy objects!
Some configurations of the cylinders are very heavy.
Lifting them incorrectly may cause injury.
O When lifting the cylinder, take steps to avoid
damaging it. Heavy cylinders must be carried by two
people or by one person with lifting aids.
CKP
WARNING
CAUTION
18

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Rtc-cgRtc-hdRtc-rrRtc-riCkp-clCkp

Table des Matières