Table top fails to clamp wheels
Handle engagement unit faulty.
➥ Check that it is synchronised properly.
➥ Replace the plate in the turntable.
➥ Check that there are no burrs.
➥ Replace the clamping handle.
Table top mounts or demounts tyres with difficulty
Insufficient belt tension.
➥ Adjust belt tension or renew it.
Vertical slide lifts too little or too far from rim
Clamping plate not adjusted.
➥ Adjust plate.
Recalibrate
.
➥
The vertical slide has difficulty rising
defective clamping plate.
➥ Renew plate.
Clamping plate not adjusted.
➥ Adjust plate.
Vertical and horizontal limit stops do not operate
No air passing through clamping handle / valve.
➥ Check the hose circuit.
➥ Replace handle / valve.
Column does not tilt
Column tilting cylinder faulty.
➥ Replace column tilting cylinder.
No air supply to cylinder.
➥ Bends in hoses.
➥ Replace valve.
➥ Check tightness of slide pivot.
Locking arm cylinders leak air
Faulty piston or seals.
➥ Replace pistons and seals.
The column tilts violently or too slowly
Incorrect release valve setting.
➥ Adjust vent regulators on control valve.
Tyre pressure gauge needle fails to return to 0
Pressure gauge faulty or damaged.
➥ Renew pressure gauge.