Picture 24 - Fume circuit inspection (X Chef Range)
4.8
CHIMNEY CLEANING
The cleaning of the chimney must be done by ex-
perienced technicians at least every six months of
normal use of the stove. Anyway, cleaning must be
done every time it becomes necessary according
to the use or to the combustible used. We recom-
mend to follow strictly all the local laws dealing
about chimney cleaning. All the parts of the chim-
ney must be cleaned.
Inside the top flue connector, on X Basic, X Plus
and X Vision Range stoves there is a device that
blocks the tar pieces eventually falling during the
cleaning of the chimney hood, in order to prevent
damages inside the stove (see picture 25). This de-
vice is useful in case of straight chimneys without
ash collection points.
Together with the cleaning of the chimney, make
also the internal cleaning of the stove, cleaning the
fume-circuits. After the cleaning of the chimney,
be sure to have closed all the inspections doors in
order to avoid draught problems.
WARNING! If the chimney cleaning is not made as recommended, fire in the flue could
happen.
Picture 25 – Tar blocking device (X Basic, X Plus, X
Vision Ranges)
88