Sensores IR
Sensor
Rango de
IR
Pantalla
CO 2
0 - 5% Vol
CO 2
0 - 10% Vol
CO 2
0 - 50% Vol
CH 4
0 - 25% Vol
CH 4
0 - 100% Vol
C 3 H 8
0 - 100% LEL
C 3 H 8
0 - 25% Vol
C 3 H 8
0 - 100% Vol
C 4 H 10
0 - 100% LEL
C 4 H 10
0 - 25 % Vol
C 4 H 10
0 - 100 % Vol
SENSORES TOXICOS ADICIONALES
Sensor
Rango
SO 2
0-20 ppm SO 2
NO 2
0-20 ppm NO 2
NH 3
0-100 ppm NH 3
PH 3
0 - 5.0 ppm PH 3
HCN
0 - 30.0 ppm HCN
Cl 2
0-20.0 ppm Cl 2
ClO 2
0-1.00 ppm ClO 2
5-4
Resolución
Repro-
cibilidad
del punto cero
0.01% Vol
≤ ± 0.05% Vol
0.01% Vol
≤ ± 0.1 % Vol
0.1% Vol
≤ ± 1.0 % Vol
0.2% Vol
≤ ± 0.5 % Vol
1% Vol
≤ ± 5 % Vol
1% LEL
≤ ± 3 % LEL
0.1% Vol
≤ ± 0.5 % Vol
1% Vol
≤ ± 3 % Vol
1% LEL
≤ ± 3 % LEL
0.1% Vol
≤ ± 0.5 % Vol
1% Vol
≤ ± 3 % Vol
Resolución
0.1 ppm SO 2
0.1 ppm NO 2
1 ppm NH 3
0.05 ppm PH 3
0.5 ppm HCN
0.1 ppm Cl 2
0.02 ppm ClO 2
Repro-
Tiempo de
cibilidad
respuesta a
del valor . 20 °C
medido
t50
≤ ±5%
≤12 s
≤ ±4%
≤12 s
≤ ±4%
≤14 s
≤ ±5%
≤12 s
≤ ±10%
≤11 s
≤ ±8%
≤11 s
≤ ±4%
≤12 s
≤ ±8%
≤12 s
≤ ±8%
≤11 s
≤ ±4%
≤12 s
≤ ±8%
≤12 s
t90
≤36 s
≤35 s
≤36 s
≤35 s
≤34 s
≤32 s
≤35 s
≤36 s
≤32 s
≤35 s
≤36 s