10 NU
Not Used
If "1" enables the display of the calculated
11 Vis. Out PID
values of the 3 PID constants
12 Kp PID
PID Proportional Constants
13 Ki PID
PID Full Constants
14 kd PID
PID Derivative Constants
15 TR PID
Recalculation time of PID constants
16 Max Out PID_I
Calculation Limit of Ki PID constant
Working range above and below the Set Point,
17 PID activation
of the PID action. % of Set Point value
Time on/off
Minimum time for switching on and off
18
min.
of resistor control outputs. % of TR PID
Sampling time for rising
19 Time er04
temperature change verification, set in parameter
20
Temperature differential to be checked in
Temperature
the time set in parameter 19.
20
er04
If "0", error checking "er04" is OFF
Sampling time for negative temperature
21 Time av01
change verification, set in parameter 22
Temperature
Negative temperature differential to be
22
av01
checked in the time set in parameter 21
Sampling time for verification of positive
23 Time av02
temperature change, set in parameter 24
Temperature
Positive temperature differential to be
24
av02
checked in the time set in parameter 23
Input status sampling time 2 :
25 Time av03
fryer basket raised
The data plate is on the side (see diagram in electric connection item) and has all the data necessary for the connection.
When fitting, the appliance must be levelled using a spirit level; slight differences of level can be adjusted by screwing
or unscrewing the adjustable feet. The main switch or the socket must be near the appliance and easily accessible. It is
advisable to place the appliance under an extractor hood so that steam is extracted rapidly. If the appliance is placed near
walls, dividing panels, kitchen furniture, decorative finishing, etc. , these should be in flameproof material; otherwise it
is necessary to cover them with non-flammable material.
Above all, it is necessary to ensure that the fire prevention norms are observed.
The installation, starting up and maintenance of the appliance must be carried out by qualified personnel. All operations
done when installing must be carried out observing the norms in force.
The manufacturer declines all responsibility in the event of incorrect functioning due to wrong installation or installation
which does not comply with the norms.
Attention! In accordance with international rules, when connecting the appliance, an automatic device enabling the
disconnection of all contacts from the mains, must be installed above it.
Installation must be carried out observing the following norms:
- Safety prescription in force
GB
INSTRUCTIONS FOR INSTALLATION
INSTALLATION
LAWS, TECHNICAL RULES AND NORMS
IE
/
0-1
0-20
0-20
0-40
0,5 - 60,0 sec.
20 - 80
0-50
5-25
1-500
0-20
0-10
1-60
1-10
1-60
0-60
26
/
/
/
0
K
1
2
K
1
4
K
1
8
K
1
10
0,1
80
%
1
10
%
1
10
%
1
120
sec.
1
2
°C
1
2
sec.
1
40
°C
1
5
sec.
1
5
°C
1
30
sec.
1