GB
IE
IT
CH
CORE PROBE
The function is present on FRYTOP(8-FT-BRF) + BRAISING PAN (8-FT-BRF) + CONTACT GRILLES (9-CWK)
THIS FUNCTION WORKS IN THE SAME WAY AS THE VACUUM CORE PROBE, BUT WITH DIFFERENT
ICONS:
core probe off
/ core probe on
/ core probe on mini
SETTING LIMITS for FRYTOP(8-FT-BRF) + BRASING PAN (8-FT-BRF):
-THE MINIMUM VALUE SET CANNOT BE LOWER THAN THE ACTUAL TEMPERATURE READ BY THE
PROBE
-THE MAXIMUM VALUE THAT CAN BE SET IS 99 °C
-WHEN THE PROBE IS NOT ACTIVE, THE MACHINE CANNOT BE SET TO A VALUE THAT IS LOWER THAN
THE CORE PROBE VALUE
ON CONTACT GRILLE COOKING CENTRE (9-CWK )
-THE MINIMUM VALUE SET CANNOT BE LOWER THAN THE ACTUAL TEMPERATURE READ BY THE
PROBE
-THE MAXIMUM VALUE THAT CAN BE SET IS 99 °C
-THIS COOKING CENTRE IS NOT THERMOSTATIC, SO THE MACHINE SET IS NOT BOUND TO THE PROBE
SET
COLD WATER LOADING
The function is available in BAIN MARIE(5-BM) + TILT. BRAISING PAN(11-BRM) + POT(12-PIA)
When activating the cooking centre, the default setting is "cold water loading off"
Pressing for 0.1 second will activate the function, the icon changes to "cold water loading on"
and a single beep
will sound. Press again for 0.1 second, to switch from "ON" to "OFF"; a single beep will sound.
-opens and closes OUTPUT 2 on BAIN MARIE(5-BM)
-opens and closes RELAY 3 on TILTING BRASING PAN(11-BRM) + POT(12-PIA)
HOT WATER LOADING
The function is available in POT(12-PIA)
When activating the cooking centre, the default setting is "hot water loading off"
Pressing for 0.1 second activates the function, the icon changes to "hot water loading on"
and a single beep will
sound. Press again for 0.1 second, to switch from "ON" to "OFF"; a single beep will sound.
-opens and closes RELAY2 on (12-PIA)
74