GB
IE
IT
CH
Abnormal temperature drop, check correct working conditions
"av02"
TEMPORARILY "PAUSES" THE HEATING
-Active on the following products: AUTOMATIC PASTA COOKER + BAIN MARIE + FRYERS(POTS?)
(products under evaluation; regardless of the "seconds" parameters, when set to 0 the warning is disabled)
-"abnormal heating" message, which attempts to protect the tank and components from overheating.
-is displayed if the rise delta of the working temperature measured over 5 seconds (parameter) exceeds 5 degrees
(parameter).
-it works by pausing the heating and temporarily disabling some functions (see individual cooking centres) and preventing
other settings except for: LANGUAGE + OFF, the warning triangle flashes and an intermittent beep will sound.
-THE FIRST ACTION IS TO TAP ON ANY POINT ON THE SCREEN, which will deactivate the beep sound and the
flashing of the warning triangle
-THE MESSAGE RESETS AND DISAPPEARS AND IS REACTIVATED AGAIN BY CLICKING ON "OK': heating
is restarted, the functions temporarily set to "off" return to "on". (the rise DELTA measurement restarts)
-THE MESSAGE RESETS WHEN ERRORS OCCUR
Abnormal temperature rise, check correct working conditions
"av03"
DOES NOT INTERVENE IN CURRENTLY ACTIVE FUNCTIONS
-Active on the following products: FRYERS + CONTACT GRILLES + TILTING BRAISING PANS
-the message "component up" warns that the resistive element/tank is not in working position.
-it occurs 30 seconds (parameter) after the opening of INPUT 2 (micro).
-it acts by preventing settings except: LANGUAGE + OFF, the warning triangle flashes and an intermittent beep will
sound.
-THE FIRST ACTION IS TO TAP ON ANY POINT ON THE SCREEN, which will deactivate the beep sound and the
flashing of the warning triangle
-THE MESSAGE DISAPPEARS WHEN CLICKING ON OK, but the 30-second countdown starts again if during this
time INPUT 2 remains open; after 30 seconds, the message reappears.
-THE MESSAGE RESETS AND DISAPPEARS AND IS REACTIVATED AFTER CLOSINGINPUT 2.
-THE MESSAGE RESETS WHEN ERRORS OCCUR
78