One of the below mentioned error codes will be displayed if an error occurs during software update.
Error codes for control software
10001501.xx.cry
Error code
Cause and solution
There is no software present in
the control unit.
• Insert a SD card with software in
the control unit and turn on the
machine.
SD card is not formatted.
• The SD card must be formatted
in a PC as FAT and place the
files down on the card or use
another SD card.
SD card contains no software.
• See page 20.
SD card has more files of the
same name.
• See page 20.
The control unit has tried to read
more data than is accessible in
the memory.
1. Insert the SD card again.
2. Replace the SD card.
3. Contact MIGATRONIC Service.
Software on the SD card is
locked for another type of control
unit.
• Use a SD card with software
that matches your control unit.
Software on the SD card is
locked for another control unit
with another serial number/ bar
code.
• Use a SD card with software
that matches your control unit.
The internal copy protection
does not allow access to the
microprocessor.
1. Insert the SD card in the
machine again.
2. Contact MIGATRONIC Service.
The memory circuit is defective
in the control unit.
• Contact MIGATRONIC Service.
The memory circuit is defective
in the control unit.
• Contact MIGATRONIC Service.
The file 100015xx.xx.cry has an
error.
1. Insert the SD card in the
machine again.
2. Exchange the SD card.
ERROR CODES
Error codes for welding program package
10646001.xx.bin
Error code
26
Cause and solution
There is no welding programs
present in the control unit
• Insert a SD card with software
in the control unit and turn on
the machine. See page 20.
SD card is not formatted.
• The SD card must be formatted
in a PC as FAT or use another
SD card.
It is only possible to have one file
with welding programs.
• Make sure that there is only one
file with the number
106460xx-xx.bin on the SD
card. See page 20.
The welding program package
does not match this control unit.
• Use a SD card with software
that matches your control unit.
The welding program package is
locked for another control unit
with another serial number/ bar
code.
• Your software package is copy
protected and cannot be used
for a control unit without the
correct license.
The control unit is defective
• Contact MIGATRONIC Service.
The file 106460xx.xx.bin is not
present on the SD card.
• See page 20.
The file 106460xx.xx.bin has an
error.
1. Insert the SD card in the
machine again.
2. Exchange the SD card.
The Omega folder with files are
not present at the card or are
saved incorrectly.
1. Make a folder
MIGA_SW / OMEGA as
described on page 20 and save
the files in the folder.
2. Exchange the SD card