One of the following mentioned error codes will be displayed if an error occurs during software update.
Error codes for MWF software 10001801.cry
Error code
Cause and solution
There is no software present in the
control unit.
Insert a SD card with software in the
control unit and turn on the machine.
SD card is not formatted.
The SD card must be formatted in a
PC as FAT and place the files down
on the card or use another SD card.
SD card contains no software.
See page 21.
SD card has more files of the same
name.
See page 21.
The control unit has tried to read more
data than is accessible in the memory.
1. Insert the SD card again.
2. Replace the SD card.
3. Contact MIGATRONIC Service.
Software on the SD card is locked for
another type of control unit.
Use a SD card with software that
matches your control unit.
Software on the SD card is locked for
another control unit with another
serial number/ bar code.
Use a SD card with software that
matches your control unit.
The internal copy protection does not
allow access to the microprocessor.
1. Insert the SD card in the machine
again.
2. Contact MIGATRONIC Service.
The memory circuit is defective in the
control unit.
Contact MIGATRONIC Service.
The memory circuit is defective in the
control unit.
Contact MIGATRONIC Service.
The file 10001801.cry has an error.
1. Insert the SD card in the machine
again.
2. Exchange the SD card.
Lacking communication to the power
source
1. The power source is a MK1 version
and cannot communicated with wire
feed unit MK2 version.
2. The intermediary cable is damaged.
3. Insert the SD card in the machine
again.
4. Contact MIGATRONIC Service
All manuals and user guides at all-guides.com
ERROR CODES
25
Error codes for welding program package
106454xx.bin
Error code
Cause and solution
There is no welding programs present
in the control unit
Insert a SD card with software in the
control unit and turn on the machine.
See page 21.
SD card is not formatted.
The SD card must be formatted in a
PC as FAT or use another SD card.
It is only possible to have one file with
welding programs.
Make sure that there is only one file
with the number 106454xx.bin on the
SD card. See page 21.
The welding program package does
not match this control unit.
Use a SD card with software that
matches your control unit.
The welding program package is
locked for another control unit with
another serial number/ bar code.
Your software package is copy
protected and cannot be used for a
control unit without the correct
license.
The control unit is defective
Contact MIGATRONIC Service.
The file 106454xx.bin is not present on
the SD card.
See page 21.
The file 106454xx.bin has an error.
1. Insert the SD card in the machine
again.
2. Exchange the SD card.
The Sigma folder with files are not
present at the card or are saved
incorrectly.
1. Make a folder
MIGA_SW / SIGMA as described on
page 21 and save the files in the
folder.
2. Exchange the SD card
The internal memory is to small
Welding program package cannot be
loaded