This box is optimised for welding in ø0.8 Fe (iron) in OMEGA 180-270,
Selection of gas type
Press the key pad until the indicator for the
selected gas type is switched on.
Reset to factory settings:
Factory settings for the selected gas type will
be reloaded when pressing the key pad until the
indicator gives a short flash.
Control knob
This knob is used for adjusting material
thickness or arc length.
Selection of material thickness
Press the
knob, until the desired value of material
thickness is shown at the display. If the machine is
connected to torch with adjustment, then the
maximum material thickness is adjusted here.
Arc length
If necessary, the arc length can be
adjusted by trimming the voltage. The
measured voltage is shown during welding.
-key pad and adjust from –9,9 to +9,9.
The adjusted parameters are saved internally in the
machine when the machine is turned off.
Simultaneously, the number of the program in use is
saved so the machine will start up in this.
BASIC CONTROL PANEL
and for welding in 1.0 Fe (iron) in OMEGA 400
-key pad and turn the control
Press the
Welding voltage indicator
The welding voltage indicator is illuminated for
reasons of safety and in order to show if there
is voltage at the electrode or torch.
Temperature fault
The indicator is switched on, when the power
source is overheated.
21