5. Setting function
To access the setting function, press the Settings button on the switch panel. There are seven Settings.
You can press the Settings button repeatedly to select the Settings
Parameter that can
be set
Clock
Temp unit
Sound
Calibration
Demo mode
12/24 H
Sabbath
Setting clock:
Touch the Settings once to enter the clock setting. By default, the current time is 12:00
At this time, you can enter the required time, for example, 11:00, you can touch 1, 1, 0, 0, the original
time number first zero, --:--, and then the number changes from right to left, press the start key to
save the current data and exit, or directly cancel not saving the current data and exit.
Setting temp unit:
Press the Settings button twice. The interface displays the default unit to set the temperature unit.
The default unit is Fahrenheit set sound
Set sound:
Sound is used to control whether or not the buttons sound, but the work tone is always present. Press
the Settings button three times. The current sound status is displayed in the middle of the screen. On
indicates that sound is enabled, and Off indicates that sound is disabled. You can switch by touching
the number key 1. Touch the Start key to confirm exit
Setting Demo mode:
This parameter is set to facilitate users to enter the demonstration mode and perform operations on
the interface in any mode. However, heating components such as the electric heat pipe are not enabled.
The default value is OFF. Press the Settings key 5 times to enter the demo, then press the number key 1
to switch. Touch the Start key to confirm exit
Touch Settings
Configurable content
repeatedly
Touch one
Set clock
Touch twice
Press1:Degree F/C
Touch three
Press1:On/Off
Press1 to change mode
Touch four
Then Press3 to increase
Press6 to decrease
Press1:On/Off
Touch five
Press1:12 H/24 H
Touch six
Press1:On/Off
Touch seven
15
Default
12:00PM
F
On
00°F (-30°F - 30°F)
Off
12 H
Off