xFUME™ ADVANCED 115V – CSA
Loosen the screws (4×) and remove the
2.
cover.
Loosen the motor clamps.
3.
Remove the motors.
4.
Dispose of the motors in accordance with
5.
local laws and directives. ð 13 Disposal
 (Page 34)
Install the new motors.
6.
Mount the mounting screws.
7.
Fix the motor clamps.
8.
Establish an electrical connection.
9.
Reverse the steps above to reassemble.
10.
11
Faults and troubleshooting
► Consult the documentation of all components used.
► Contact your retailer or ABICOR BINZEL in the event of questions or problems.
Fault
Extraction volume too low.
BAL.0882.0 • V01
11 Faults and troubleshooting
Cause
Filter elements saturated.
Dust collection bin leaking.
Extraction hose blocked.
Extraction hose faulty.
Correction
► Replace the filter cartridges.
ð 10.3 Replacing filter
cartridges (Page 27)
► Check the dust collection bin
and fit it properly. ð 10.2
Emptying the dust collecting
container (Page 26)
► Clean extraction hose.
► Replace extraction hose.
ð 7.1 Attaching the
extraction hose (Page 16)
EN - 31