10 Maintenance and cleaning
Remove the carbon brushes.
5.
Dispose of the carbon brushes in
6.
accordance with local laws and directives.
ð 13 Disposal (Page 34)
Insert the new carbon brushes and mount in
7.
reverse order.
10.5
Replacing the motors
Loosen the tension locks on the sides and
1.
remove the upper part of the device using
the handle.
EN - 30
Electric shock due to electronic component damage
When replacing the motors, electrical connections must be disconnected and
reconnected. Fatal electric shock may occur if electronic components become
damaged or improperly uninstalled in the process.
► The motors should be replaced only by a qualified electrician.
Electric shock due to damaged or improperly installed cable
The use of damaged or improperly installed cables may result in a potentially fatal
electric shock.
► Check all live cables and connections for proper installation and damage.
► Have any damaged, deformed, or worn parts replaced by a qualified electrician
only.