8 Operation
If the welding process is interrupted, automated cleaning of the filter membranes occurs after a run-
on time of 20 seconds.
To activate the automatic start/stop
1.
mechanism, set the <Auto/Manual> switch
to <Auto>.
Set the <On/Off> switch to <On>.
2.
The filter membranes are cleaned once.
Once the welding process begins, the device
receives a signal from the current clamp and
automatically starts the fume extraction process.
If the welding process is interrupted, extraction
stops after 20 seconds. Only then the cleaning
process is carried out automatically.
The filter membranes must be cleaned regularly to ensure continuous extraction. The cleaning
interval depends on the welding process. We recommend that the filter members are cleaned
every 2 hours, however no later than when the service LED illuminates. The service life of the filter
membranes can be lengthened if they are cleaned before the service LED illuminates.
Running the cleaning process manually
Briefly set the <On/Off> switch to <Off>.
1.
EN - 22
Shorter service life due to lack of cleaning
If the welding process is interrupted, automated cleaning of the filter membranes occurs
only after a run-on time of 20 seconds. If the welding process is started beforehand, no
cleaning takes place. The service life of the filter membranes is shortened.
► Ensure that the welding process is interrupted at least every 2 hours for a minimum of
20 seconds, or perform manual cleaning.
xFUME™ ADVANCED 115V – CSA
NOTE
BAL.0882.0 • V01