10 Maintenance and cleaning
Interval
After 2 operating hours or
when the service LED
illuminates
Daily
Weekly
Monthly
After approx. 500 operating
hours
After two carbon brush
replacements
Table 4
10.2
Emptying the dust collecting container
Loosen the star screws on the dust collecting
1.
container.
Pull out the dust collecting container.
2.
Empty the dust collection container in the
3.
dust collecting bag.
Seal the dust collecting bag and dispose of
4.
it in accordance with local laws and
directives. ð 13.2 Disposal of welding dust
 (Page 34)
Insert the dust collection bin again.
5.
Hand-tighten the star handles.
6.
EN - 26
Job
► Run the cleaning process ð 8 Operation (Page 20)
► Change filter cartridges. ð 10.3 Replacing filter cartridges
 (Page 27)
► Empty the dust collection bin. ð 10.2 Emptying the dust
collecting container (Page 26)
► Check the operating hours meter.
► Check the device for visible damage.
► Carbon brushes must be replaced only by a qualified
electrician. ð 10.4 Replacing the carbon brushes
 (Page 29)
► Have motors replaced by a qualified electrician. Replacing
the motors
Maintenance and Cleaning Intervals