8 Operation
8
Operation
8.1
Setting the extraction volume
To set the extraction volume, turn the output
1.
regulator to the right or left.
8.2
Manual operation
The device is operated in manual mode (deactivated automatic start/stop mechanism) as follows:
EN - 20
Health risk due to inhalation of harmful welding, grinding, and cutting
fumes
Welding, grinding and thermal cutting processes produce fumes containing harmful
dust particles that can settle on surfaces and be released into the ambient air. The
respiratory system can be damaged if inhaled.
► Check and wear your personal protective equipment.
► Only use the unit in rooms which are sufficiently ventilated.
► Make sure that all the seals on the unit are free of dirt.
► Always only operate the unit with the designated filtration system.
► Always only operate the unit with the dust collecting container closed.
► Do not open the dust collecting container until at least one minute after switching the
unit off.
► Keep the unit closed during operation and the dedusting process.
► Remove dust deposits in the surrounding area immediately using an industrial
vacuum cleaner of dust class H or a damp cloth.
Fire hazard due to improper use
Improper use of the device can result in fire. This may result in serious burns.
► Do not use the device in areas subject to dust or gas explosion hazards.
► Do not use the device to extract welding fumes that result from welding oil-wetted
parts.
► Do not use the device to extract flammable substances and liquids.