Maintenance and cleaning
Regular maintenance and cleaning are prerequisites for a long service life and perfect function.
The regular removal of dust can extend the service life of the filter cartridges. The maintenance
interval is determined by the working environment and operating time of the units. If the unit is
operated for longer than 8 hours per day, the maintenance interval should be adapted according
to requirements.
10.1
Maintenance and cleaning intervals
The given intervals are for guidance and refer to one-shift operation. We recommend documenting
the checks. At least the test date, the defects found and the name of the tester should be
documented.
BAL.0882.0 • V01
Health risk due to inhalation of harmful welding, grinding, and cutting
fumes
Welding, grinding and thermal cutting processes produce fumes containing harmful
dust particles that can settle on surfaces and be released into the ambient air. The
respiratory system can be damaged if inhaled.
► Check and wear your personal protective equipment.
► Only use the unit in rooms which are sufficiently ventilated.
► Make sure that all the seals on the unit are free of dirt.
► After cleaning and maintenance work check all screwed joints for a tight fit, leaks,
chafing points. Tighten any loosened screwed joints. Correct any faults found
immediately.
► Remove dust deposits in the surrounding area immediately using an industrial
vacuum cleaner of dust class H or a damp cloth.
Electric shock due to damaged or improperly installed cable
The use of damaged or improperly installed cables may result in a potentially fatal
electric shock.
► Check all live cables and connections for proper installation and damage.
► Have any damaged, deformed, or worn parts replaced by a qualified electrician
only.
Risk of injury due to unexpected start
If power is supplied during maintenance, cleaning or disassembly, rotating parts can
start running unexpectedly and lead to injuries from cuts.
► Switch off the device.
► Disconnect all electrical connections.