xFUME™ ADVANCED 115V – CSA
10.4
Replacing the carbon brushes
The service life of the first set of carbon brushes is 500 hours. The service life is reduced by 20%
each time the carbon brush is replaced. The carbon brushes may not be replaced more than two
times in total. After that, the motor must be replaced.
Loosen the tension locks on the sides and
1.
remove the upper part of the device using
the handle.
Loosen the screws (4×) and remove the
2.
cover.
Remove the carbon brush covers (2×).
3.
Press down the hook of the cable lug with a
4.
screwdriver and remove the cable lug of the
connecting cable from the carbon brushes
(4×).
BAL.0882.0 • V01
Electric shock due to electronic component damage
When replacing the carbon brushes, electrical connections must be disconnected and
reconnected. Fatal electric shock may occur if electronic components become
damaged or improperly uninstalled in the process.
► The carbon brushes should be replaced only by a qualified electrician.
10 Maintenance and cleaning
WARNING
EN - 29