7 Commissioning
7.4
Establishing the power supply
► Note the safety instructions. Safety instructions for the electrical power supply
For mains connection and fuse protection, see:
ð 5 Technical data (Page 15)
ð 16 Circuit diagram (Page 37)
The mains plug is not mounted on the power supply cable.
► Attach and plug in an appropriate mains plug (customer-specific) on the power supply cable.
EN - 18
Electric shock due to damaged or improperly installed cable
The use of damaged or improperly installed cables may result in a potentially fatal
electric shock.
► Check all live cables and connections for proper installation and damage.
► Have any damaged, deformed, or worn parts replaced by a qualified electrician
only.
Fire hazard due to improper mains connection
A fire can be caused by an improper mains connection. Serious burns can be the result.
► Make sure that the operating voltage stated on the rating plate matches the mains
voltage.
xFUME™ ADVANCED 115V – CSA
WARNING
WARNING
BAL.0882.0 • V01