Télécharger Imprimer la page

Parkside PMSG 200 A2 Consignes D'utilisation Et De Sécurité page 25

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 59
NOTE: Guideline values for the welding current to be used, depending on the electrode diameter
can be taken from the following table.
Ø Electrode
1.6 mm
2.0 mm
2.5 mm
3.2 mm
ATTENTION: Do not bring the earth terminal
contact with one another.
ATTENTION: When welding with rod electrodes, the electrode holder
must be connected in accordance with the information from the electrode manufacturer.
Hold the welding mask
To stop the procedure, set the main switch ON/OFF
ATTENTION: When the thermal sensor is triggered, the O.H. display lights up.
it will not be possible to continue welding. The device will continue to run so that the fan can cool the
device. As soon as the device is ready for operation again, the O.H. display goes out.
function can now be used again.
ATTENTION: Do not dab on the workpiece with the electrode. It could be damaged and make
it more difficult to ignite the arc. As the soon as the arc is ignited, try to maintain a distance to the
workpiece which corresponds to the diameter of the electrode being used. The gap should remain as
constant as possible while you are welding. The inclination of the electrode in the direction of operation
should be 20–30 degrees.
ATTENTION: Always use pliers to remove used electrodes or hot workpieces. Make sure that the
electrode holder is always placed onto an insulated surface after welding. The slag can only be removed
from the seam once it has cooled down. To continue welding an interrupted seam:
First remove the slag at the connection point.
The arc is ignited in the weld groove, guided to the connection point, melted properly and finally the
weld seam is continued.
ATTENTION: Welding generates heat. Therefore the welding device must run idle for at least half
an hour after use. Alternatively, you can leave the device to cool for an hour. The device can only be
packed away and stored once the temperature of the device is normal again.
ATTENTION: A voltage which is 10% below the rated input voltage of the welder can have the
following consequences:
The power to the device will reduce.
The arc stops or becomes unstable.
Welding current
40–60 A
60–80 A
80–100 A
100–140 A
in front of your face and start the welding procedure.
22
and the electrode holder
4
to "O" ("OFF") position.
5
GB/IE/NI/CY/MT
/electrodes into direct
34
and the earth terminal
34
In this case,
37
. The welding
37
4
25

Publicité

loading

Ce manuel est également adapté pour:

445950 2307