35. Adjust for Out of Plumb - Low
Greater than
2" (51 mm)
WARNING: Risk of personal injury. Verify that the pivot panel is resting on the install block and that the install
block is securely resting on the threshold before proceeding.
WARNING: Risk of personal injury. Two people are recommended for this step. Place one person inside the
shower and another person outside the shower to adjust the pivot panel for plumb.
From inside the shower, loosen (do not remove) the screws holding the soft-close assembly brackets to the header.
Add one shim. Check if the distances between the edge of the pivot panel and the wall at the top and bottom are equal.
If the distances are equal: Tighten the screws holding the soft-close assembly brackets to the header.
If the distances are not equal: Add shims one-by-one until the distances between the edge of the pivot panel and the
wall at the top and bottom are equal. Secure the shims to the install block with tape. Tighten the screws holding the
soft-close assembly brackets to the header.