Observe the following measurement techniques:
NOTE
– If a reading shows 0 Hz or is unstable, the input signal may be below or near the trigger
level. You can usually correct these problems by manually selecting a lower input
range, which increases the sensitivity of the multimeter.
– If a reading seems to be a multiple of what you expect, the input signal may be
distorted. Distortion can cause multiple triggerings of the frequency counter. Selecting
a higher voltage range might solve this problem by decreasing the sensitivity of the
multimeter. In general, the lowest frequency displayed is the correct one.
Press
Press
than 1 second to exit the frequency measurement function.
Keysight U1281A/U1282A User's Guide
to scroll through the frequency, pulse width, and duty cycle measurements.
Hz
Save
to scroll back to the frequency measurement mode, and hold
Hz
Save