Technical Data; General; Tp 4000 Cel; Tp 4000 Cel Mv - Fronius TransPocket 4000 CEL Instructions De Service

Source de courant électrodes
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Technical data

General

If the power source is designed for a special voltage, the technical data on the rating
plate applies. The mains plug, mains lead and their fuse protection must be rated
accordingly.

TP 4000 CEL

Mains voltage
Mains voltage tolerance
Mains fuse protection
Mains connection
Primary continuous power
Cos phi
Welding current range
Welding current at
Standardised working voltage
Maximum working voltage
Open circuit voltage (pulsed)
Degree of protection
Mark of conformity
Type of cooling
Insulation class
Dimensions l x w x h
Weight
Idle state power consumption at 400 V
Power source efficiency at 380 A / 35.2 V
1)
2)

TP 4000 CEL MV

Mains voltage
Mains voltage tolerance
104
1)
100% D.C.
10 min / 40°C
10 min / 40°C
10 min / 40 °C
Connected to public grids with 230 / 400 V and 50 Hz
D.C. = Duty cycle
2)
MMA
TIG
40% D.C.
60% D.C.
100% D.C.
MMA
TIG
MMA
Peak value
Average value
3 x 400 V
+/- 15%
35 A slow-blow
Restrictions possible
12.9 kVA
0.99
10 - 380 A
10 - 380 A
2)
380 A
360 A
2)
320 A
2)
20.4 - 35.2 V
14.5 - 33 V
53 V (380A)
80 V (10 A)
95 V
60 V
IP 23
S, CE
AF
F
625 x 290 x 475 mm
24.6 x 11.4 x 18.7 in.
36.1 kg
79.6 lbs
222 W
89 %
10 - 380 A
10 - 380 A
+/- 10%

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Transpocket 5000 cel