Technical data
General
Voltage rating (V-peak)
-
-
Torch trigger technical data:
-
-
The torch trigger can only be operated within the limits of the technical data.
This product meets the requirements set out in standard IEC 60974-7/- 10 CI. A.
MTG 2100 S
Shielding gas (Standard EN 439)
DC welding current
at 10 min / 40 °C (104 °F)
Electrode diameter
Welding torch length
1)
MTG 2500 S
Shielding gas (Standard EN 439)
DC welding current
at 10 min / 40 °C (104 °F)
Electrode diameter
Welding torch length
1)
For hand-held welding torches: 113 V
For machine-guided welding torches: 141 V
U
= 50 V
max
I
= 10 mA
max
D.C. = duty cycle
D.C. = duty cycle
MTG 2100 S
CO2
1)
35 % D.C.
/ 210 A
1)
60 % D.C.
/ -
1)
100 % D.C.
/ -
0.8 - 1.2 mm
(0.032 - 0.047 in.)
3.5 / 4.5 m
(11 ft. + 5.8 in. / 14 ft.+
9.17 in.)
MTG 2500 S
CO2
1)
35 % D.C.
/ 250 A
1)
60 % D.C.
/ -
1)
100 % D.C.
/ -
0.8 - 1.2 mm
(0.032 - 0.047 in.)
3.5 / 4.5 m
(11 ft. + 5.8 in. / 14 ft.
+ 9.17 in.)
MIXED
1)
35 % D.C.
/ 190 A
1)
60 % D.C.
/ 170 A
1)
100 % D.C.
/ 140 A
0.8 - 1.2 mm
(0.032 - 0.047 in.)
3.5 / 4.5 m
(11 ft. + 5.8 in. / 14 ft.+
9.17 in.)
MIXED
1)
35 % D.C.
/ 230 A
1)
60 % D.C.
/ 200 A
1)
100 % D.C.
/ 170 A
0.8 - 1.2 mm
(0.032 - 0.047 in.)
3.5 / 4.5 m
(11 ft. + 5.8 in. / 14 ft.
+ 9.17 in.)
45