Aspen 2 MAXI
English
Cleaning the condenser
The condenser (Fig. 6 Rif. 2) should be cleaned once a month so as to eliminate the dust accumulated:
- Remove the covering sheet metal or grate;
- Proceed with cleaning using brushes with hard bristles (not metal) or a vacuum cleaner, paying
attention not to bend or damage the condenser fins.
Cleaning the water collection tray
The tray is removable for cleaning:
- Remove the tray and clean it.
After cleaning, reassemble the dry elements and plug the cabinet in. Once the internal operating
temperature has been reached, the products to be displayed can be replaced inside the cabinet.
ATTENZIONE!: If using a water jet cleaner to clean the interior, use a LOW
PRESSURE system. Take special care NOT direct the jet onto painted or plasticised
surfaces and keep a minimum distance of 30 cm from the surface to be cleaned (Fig.
4).
N.B.Make sure that fans, ceiling lights, electric cables and any other electric equipment are not
wetted during cleaning.
19.Dismantling the cabinet
The unit must be disposed of in accordance with your country's waste management legislation and in
respect of our environment.
This product is considered by current legislation as hazardous waste. It must therefore be collected
separately and cannot be treated as household waste nor sent to a landfill. Before disposing of the unit,
the coolant must be collected and the lubricant oil removed. The user is responsible for delivering the
product for disposal to the collection centre specified by the local authorities or manufacturer for the
recovery and recycling of materials. This product consists of 75% recyclable materials.
Materials used in construction:
- Tubes, steel profiles and sheets: lower frame, rods and shelves
- Copper, Aluminium:
- Galvanized steel sheet:
- Foam polystyrene (R134a):
- Tempered glass:
- Wood:
- ABS:
- Polystyrene:
- Polycarbonate:
- Methacrylate:
This product contains HFC, a refrigerating gas with a high Global Warming Potential (GWP).
ARNEG equips its cabinets with refrigeration units incorporating the following types of refrigerating
gasses:
R 134a; GWP
= 1300
(100)
R 404A; GWP
= 3750
(100)
in the family of the HFCs, which are fluoridated gasses with a high global warming potential (GWP),
regulated by the Kyoto protocol (check on the rating plate or adhesive label on the compressor which
of these two gasses is used in the unit).
Therefore:
THE COMPONENTS OF THE REFRIGERATING CIRCUIT MUST NOT BE CUT OR SEPARATED,
BUT MUST BE TAKEN INTACT TO CENTRES SPECIALISED IN RECYCLING REFRIGERATING
GAS.
This unit is hermetically sealed and the refrigerating gas load is under 3 kg.
For this reason it is not subject to the requisite of an installation booklet and periodic
inspections for leakage of the refrigerating gas (Presidential Decree no. 147 of February 15, 2006
Art. 3 and 4).
20.Prohibitions and prescriptions
It is recommended that the Installation and Use Manual be read carefully, so that the operator, in the
case of malfunction, is able to provide precise information to Technical Assistanceby telephone.
Before carrying out any maintenance work on the refrigerator unit, please ensure that the electrical
supply is disconnected.
34
refrigerating circuit, electric system and upper ceiling light
motor base, lower panels, painted panels, base structure
thermal insulation
upper shelves (glass sides)
foamed tray side frames
bumper and handrail
thermoformed side panels
lamp protection
sides
05060101 01 06/05/2010