- Reposition the lamp assembly and fasten it to the spring 5;
- Restore power supply.
16.Back coverings (Fig. 9)
To prevent unnecessary dispersion of the cold and guarantee the hygiene of the goods displayed,
during the night or in case of electrical blackouts, sliding covers are available, as optional, for the
back (Rif. 14).
N.B.For cabinets equipped with interior lighting, switch the lights off before closing the cabinet.
17.Multiplexing of cabinets (Fig. 10)
MULTIPLEXING KIT
Pos.
1
Alignment pin Ø 3x40
2
Alignment pin Ø 4x80
3
No-frost joint cover
4
Nut M8
5
Galvanized washer 8x17
6
Bracket for joing multiplex cabinets
7
Hex head galvanized M8x80 screw
8
Galvanized countersunk cyl. hex. head M8x120 screw
9
Hex head galvanized M6x10 screw
10
Uprights plate joint
11
Screw 4,2x19
18.Maintenance and cleaning
ATTENZIONE!: BEFORE CARRYING OUT ANY MAINTENANCE WORK OR
CLEANING, FIRST DISCONNECT THE UNIT FROM THE VOLTAGE SUPPLY
BY MEANS OF THE GENERAL SWITCH. ALWAYS WEAR PROTECTIVE
GLOVES FOR CLEANING.
Food products can deteriorate due to microbes and bacteria.
Respecting hygiene norms is indispensable in order to guarantee protection of consumer health, as
well as respecting the chain of refrigeration, for which the sales point is the last controllable ring.
Cleaning of refrigeration units should be carried out as follows:
Cleaning of external parts (Daily / Weekly)
- On a weekly basis, clean the external parts of the unit, using neutral household detergents or soap
and water.
- Rinse with clean water and dry with a soft cloth.
- DO NOT use abrasive products or solvents that can affect the unit surface.
- DO NOT spray water or detergent directly on the electrical parts of the unit.
- DO NOT touch the unit with wet or damp hands or feet
- DO NOT use the unit if barefoot
- DO NOT use alcohol to clean the methacrylate parts (Plexiglas).
Cleaning of internal parts (Monthly)
Cleaning the unit's internal parts is done to destroy pathogenic micro-organisms so as to ensure
protection of merchandise.
Before beginning to clean the inside of the unit, it is necessary to:
- Completely remove all merchandise inside;
- Disconnect the unit's power supply using the main switch;
- Remove any removable parts, including display plates, grills, etc. These should be washed with
warm water and detergent that contains disinfectant, and then dried carefully;
- Carefully clean the tank, drip, and water discharge protection grill, eliminating all foreign bodies that
may have fallen into the suction grill, lifting the fan plate if necessary.
- If anomalous ice has formed, contact a Qualified Refrigeration Technician for assistance.
Complete the cleaning operation by reattaching the dry removable elements and by restoring the
electrical supply. Once internal operating temperature has been reached, the unit can be loaded with
the products to be displayed.
N.B.Avoid wetting fans, lights, electric cables, and all electrical devices in general during
cleaning operations.
050600101 01 06/05/2010
ASPEN
Description
Aspen 2 MAXI
Code
02940045
02940652
02940538
04230600
04480104
02211300
04711030
04711065
04710033
02210102
04706002
English
33