Télécharger Imprimer la page

Arneg Aspen 2 MAXI Manuel D'utilisation page 29

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 57
1. Introduction - Scope of the manual/Field of application
This instruction manual refers to the Aspen 2 Maxi line of refrigerated cabinets.
The scope of the information that follows is that of providing indications concerning:
use of the cabinet - technical characteristics - installation and assembly - information for the person-
nel in charge of its use - maintenance operations.
This manual should be considered part of the cabinet and must be kept for the entire life of the cabi-
net itself.
The manufacturer holds itself exempt from all responsibility under the following circumstances:
Improper use of the cabinet - incorrect installation, not carried out according to the norms indicated
- defects in the electric supply - serious lacks in required maintenance - unauthorised changes and
operations - use of non-original spare parts - partial or total non-observance of instructions given.
N.B.Electrical appliances can be dangerous to your health.
The norms and laws in force must be respected during installation and use.
Anybody using this cabinet must read this manual.
2. Presentation - Foreseen use (Fig. 1)
The Aspen 2 Maxi line of refrigerated cabinets is a complete line of display cases suitable for the
storage and sale of pork products, dairy products, prepared dishes, meat, poultry, fresh fish,
bread, pastry, frozen foods and hot dishes.
The cabinets are designed to be used with either a remote or an incorporated condenser unit.
They come in a range of models to meet the needs of the sales outlets and modern distribution
methods. The range is complete with corner cabinets, with open and closed corner 90° or 45°.
The current versions include:
- Aspen 2 Maxi VCA - VCB in lengths 937-1250-1875-2500-3125-3750;
- Aspen 2 Maxi SELF in lengths 937-1250-1875-2500-3125-3750.
For the other Aspen 2 Maxi versions specific manual are provided.
3. Norms and certifications
All the refrigeration unit models described in the usage manual for the Ankara 3 series meet the
essential requirements for safety, health, and protection required by the following European directives
and laws:
- Machines Directive 2006/42 EC;
harmonised standards applied: EN ISO 14121:2007; EN ISO 12100-1:2005; EN ISO 12100-2:2003
- Electromagnetic Compatibility Directive 2004/108/EC;
harmonised standards applied: EN 61000-3-2:2006; EN 61000-3-12:2005; EN 55014-1:2006;
EN 55014-2:1997;
- Low Voltage Directive 2006/95/EC;
harmonised standards applied: EN 60335-1:2008; EN 60335-2-89 :2002/A2:2007
European Regulation EC-1935/2004 on materials and articles intended to come into contact with food
- standards applied: EN 1672-2
They are excluded from the field of application of Directive EEC 97/23 (PED) on the basis of that
specified by Article 3 paragraph 3 of the Directive.
A copy of the declaration of product conformity can be requested by filling in the form available
at the internet address:
The performance of these refrigerated units has been determined by means of tests carried out in
accordance with standard UNI EN ISO 23953-2: 2006 in the environmental conditions corresponding
to climate class 3 (25 °C , 60% Rel. Humidity)
Environmental climatic classes according to UNI EN ISO 23953 - 2
Climatic class
Temp. dry bulb
1
2
3
4
5
6
4. Identification - Nameplate (Fig. 2)
The technical nameplate indicating the technical characteristics is located inside the cabinet:
050600101 01 06/05/2010
http://
www.arneg.it/conformity
Relative humidity
16°C
80%
22°C
65%
25°C
60%
30°C
55%
40°C
40%
27°C
70%
Aspen 2 MAXI
Dew point
12°C
15°C
17°C
20°C
24°C
21°C
English
29