Screw in the extension that comes supplied with the arm.
FITTING THE END-CAPS
Screw in the required end-cap kit for the riveting procedure into the arm support. Before each assembly, check that the
die and rivet support are correctly aligned (see page 8) and tighten.
Once the die and the header die support are in place, finish tightening with the special
key supplied. Check that the tips are securely in place after each riveting procedure. Loosening is
dangerous and can damage the riveter.
50 KN ADAPTOR
WHEN USING A 50 kN adaptor (ref. 064867), connect the adaptor's jack
plug into the socket provided on the handle of the riveting device.
The indicator light located on the side of the 50 kN adaptor follows the
same operating procedure as the indicator light located on the riveter (see
'Riveter indicator light' section).
32
WORKSTATION GYSPRESS 10T PP CONTROL
Die/rivet support
The riveter is now operational.
Rivet die
EN