MAIN MENU
To access the general menu from the general display, press button 1
Navigating between the different options is done using the dials and push buttons.
Settings
System
Portability
Verification
PRODUCT SETTINGS
Language: There is a wide choice of available interface languages (French, English, German, etc.).
Unit of measurement: There is a selection of measurement units: International (SI) or Imperial (USA).
• Screen brightness Adjust the brightness of the interface screen (set from 1: very dark - 10: very bright)
SYSTEM
Device name: Information relating to the machine's name and customisation options can be found by pressing
interface screen.
Clock: Setting the time, date and format (AM / PM).
Reset: Resets the product's settings:
Partial: resets back to manual mode at 50 kN with a HR110 arm
Total: all device's configuration data will be reset to factory settings
VERIFICATION
Feature that checks that the riveter's pressure meets the set-point pressure.
Fitting the Evolution pressure sensor (ref. 071759) The sensor's drag pointer must be zeroed before starting the pro-
cedure.
Once the verification procedure has started, animations will explain how to operate the machine. The pressure reading
must be taken at the red needle and entered in the machine.
TRACEABILITY
This interface allows the user to record riveting operations as a site report and export this information to a USB stick
so that it can be opened and used on a PC with the GYSPOT computer software (see 'GYSPOT software' section).
TURNING on the traceability feature
To turn on the traceability feature, go to the Traceability menu and select it «START».
The left-hand side of the screen lists the previously created worksite tasks.
The user can sort these tasks by name or by date by pressing push-button 2.
Holding down this button deletes the active site or all the worksite tasks saved on the machine.
The right-hand side of the screen displays the worksite task's date and time of recording as well as the number of
rivets carried out.
Select and continue with an existing worksite task by pressing button 4 «REC»
Create a new worksite task by pressing push-button
28
WORKSTATION GYSPRESS 10T PP CONTROL
1: Back
2: Validation
Traceability
3: The current tab's icon
Information
.
. Enter a name for this worksite task by pressing button 3
EN
the
.