frequently both inside and out (AT LEAST ONCE A
MONTH); always follow the instructions given in the
maintenance manual. ● Extra care must be taken when
frying to prevent the oil from overheating and catching fire.
● Please note! The accessible parts of the device may
become hot when the hob is switched on. ● Please note!
Do not connect the product to the mains until the
installation is complete. ● Only use the fastening screws
supplied with the product for installation, or if not supplied,
purchase the correct type of screws. Use screws of the
right length, as indicated in the installation guide. ● This
manual must be stored for future consultation at any time. If
sold, transferred or moved, it must remain with the product.
● Range hoods and other cooking fume extractors may
adversely affect the safe operation of appliances burning
gas or other fuels (including those in other rooms) due to
back flow of combustion gases. These gases can
potentially result in carbon monoxide poisoning. After
installation of a range hood or other cooking fume
extractor, the operation of flued gas appliances should be
tested by a competent person to ensure that back flow of
combustion gases does not occur.
ELECTRICAL CONNECTION SAFETY
● Disconnect the product from the mains. ● The
installation must be carried out by professionally qualified
personnel with knowledge of the regulations in force for
installation and safety. ● The manufacturer disclaims all
liability for persons, animals or property if the guidelines
provided in this chapter are not followed. ● The power
cable must be long enough to allow removal of the hob
from the worktop. ● Check that the voltage on the rating
plate on the bottom of the product corresponds to that of
the domestic environment where it will be installed. ● Do
not use extension cords. ● The earth cable must be 2cm
longer than the other cables. ● If the product is not
equipped with a power cable, use one with a minimum
conductor diameter of 2.5 mm2 for power up to 5500 Watt;
for higher power levels, the diameter must be 4 mm2. ●
The temperature must not reach 50°C above room
temperature anywhere along the cable. ● The product is
intended to be permanently connected to the mains,
therefore, make the connection to the mains using an
approved omnipolar switch that guarantees complete
disconnection from the mains in category III overvoltage
conditions, and which is readily accessible after the
installation.
● Please note! The interconnection cable must be
replaced by the authorised customer service representative
or by a person with similar qualifications.
● Please note! Before reconnecting the circuit to the
mains power supply, make sure that it is working correctly,
always check that the power cable is correctly installed.
INSTALLATION SAFETY
● The electrical and mechanical installation must be
performed by qualified personnel.
● Before starting the installation: After unpacking the
product, check that it has not been damaged during
transport and in the case of problems, contact your dealer
or Customer Service, before proceeding with the
installation; Check that the purchased product is the right
size for the installation location; Check for accessories
inside the packaging (placed there for ease of transport,
such as bags containing screws, the warranty certificate,
etc.). Remove and keep them safe; Also check that there is
a power socket near the installation area
● Preparing the cabinet for installation:
• Create the cut-outs in the cabinet before inserting the hob
and carefully remove shavings or sawdust.
The minimum distance between the hob and the wall must
be at least 50mm from the front, at least 50mm from the
sides and at least 550mm from the upper wall units.
NB: when designing the space, the kitchen manufacturer's
instructions must be followed.
• Important: use a single component adhesive sealant (S)
that can withstand high temperatures up to 250°; before
installation, the surfaces that need to be glued must be
thoroughly cleaned, removing all substances that may
compromise adhesion (e.g. release agents, preservatives,
grease, oils, powders, old adhesive residue, etc.); the
adhesive must be evenly spread along the entire perimeter
of the frame; after gluing, leave the adhesive to dry for
about 24 hours.
● Please note! Failure to install screws and fasteners in
accordance with these instructions may result in electrical
hazards.
● Note: for correct installation of the product, it is
recommended to tape the pipes using an adhesive with the
following characteristics: soft elastic PVC film, with acrylic-
based adhesive; complies with DIN EN 60454 regulations;
flame retardant; excellent resistance against wear; resistant
to temperature fluctuations; can be used at low
temperatures.
END-OF-LIFE DISPOSAL
This device is marked in compliance with the
European Directive 2012/19/EC - UK SI 2013
No.3113, Waste Electrical and Electronic Equip-
ment (WEEE).
Make sure that this product is disposed of correctly. The
user helps prevent potential negative consequences for the
environment and for health. The symbol on the product or
accompanying documentation indicates that this product
should not be treated as household waste but should be
handed over at a suitable collection point for the recycling
of electrical and electronic equipment. Dispose of it in
accordance with local regulations for waste disposal. For
further information about the treatment, recovery and
recycling of this product, please contact your local
authority, the collection service for household waste or the
shop from where the product was purchased.
REGULATIONS
This appliance, intended to come into contact with
foodstuffs, complies with Regulation (EC) no.1935/2004
12