Télécharger Imprimer la page

Fronius Selectiva 4.0 UL B1 Instructions De Service page 19

Publicité

Les langues disponibles

Les langues disponibles

Danger due to overheating as a result of incorrectly laid mains/charging cables.
Risk of damage to the mains/charging cables.
Charging cable
Danger from flying sparks due to improper disconnection of the charging plug.
This can result in severe personal injury and damage to property. The resulting
sparks can ignite the charging gases that form during charging and cause a fire or
explosion
Warning notices
A number of safety symbols can be seen on the battery charger. The safety sym-
on the device
bols must not be removed or painted over.
CAUTION!
The mains/charging cable may only be replaced by a qualified electrician.
Lay the mains/charging cable without a loop.
Do not cover the mains/charging cable.
Charging cables longer than 16 ft. 4.85 in. (5 m) must be laid individually (no
bundling).
Charging cables longer than 16 ft. 4.85 in. (5 m) can have an increased sur-
face temperature (be aware of hot surfaces).
In the following cases, pay special attention that the surface temperature of
the charging cables does not exceed 176°F (80°C):
- Ambient temperature is 86°F (30°C) or more
WARNING!
End the charging process via the battery charger and, after the charging
cables have cooled down, wind them up or, if available, place them on the
cable holder.
19