Status codes in the event of a TagID error
No.
Cause/Remedy
(200) Set technology on the battery charger is not compatible with the connec-
ted battery.
(201) The nominal voltage of the battery is not supported by the battery char-
ger or is prevented by a battery charger setting
(202) The battery charger power is not high enough to charge the connected
battery
(203) CAN communication to TagID could not be established
(204) TagID data could not be read
(205) TagID update could not be performed
(206) TagID temperature sensor is defective
(207) TagID voltage sensor is defective
(208) Battery master data of the TagID is invalid or not available
(209) Defective EEPROM memory
(210) Defective flash memory
(211) Invalid device signature
(212) TagID data could not be written
(213) The charger power is not sufficient to charge the battery in the desired
charging time
(214) Too much power dissipation on the DC path
(215) TagID level sensor is mounted in the wrong cell or is defective
(216) TagID SoftwareCrash
Status codes in the event of an error in the primary circuit
No.
Cause/Remedy
(500) Temperature sensor module 1 (top) defective
(501) Temperature sensor module 2 (bottom) defective
(502) Temperature sensor PCB defective
(503) Primary overtemperature
(504) Fan blocked/defective
(505) Over-/undervoltage in intermediate circuit
(506) Asymmetry in intermediate circuit
(507) Primary supply voltage out of tolerance
(508) Grid failure
(509) Incorrect device configuration