Status codes in the event of a charging error
No.
(31)
(32)
(33)
(34)
(35)
(36)
(37)
(38)
(39)
Status codes in the event of a CAN error (battery)
No.
(51)
(52)
(53)
(54)
(55)
(56)
(57)
(58)
Status codes in the event of a gateway error
No.
(101) CAN Connect setting is active and no CAN connection could be estab-
(102) Gateway has no connection to the back-end.
62
Battery too hot (only with external temperature sensor)
Battery undertemperature (only with external temperature sensor)
Cell defect detected
Battery not supported
Battery heavily discharged - safety charge in progress
Incorrect battery polarity
Thermal runaway
Cause/Remedy
Time exceeded in the I1 phase
Time exceeded in the U1 phase
Battery overvoltage in the I2 phase
Ah exceeded
Time exceeded in the I2 phase
Target voltage in the I2 phase not reached (only with format curve)
RI charge error
Set charging time cannot be reached
Time exceeded during RI charge
Cause/Remedy
Battery not responding
Battery data cannot be queried
Battery voltage not supported
Communication error
Battery error
Battery does not switch on
Message time limit exceeded
Login failed
Cause/Remedy
lished to the gateway for at least 2 minutes.