Safety rules - required for Canada
General and
1
electrical risks
2
3
4
5
6
Minimum AWG size of an extension cable for the mains connection
25 ft (7.6 m)
50 ft (15.2 m)
75 ft (22.9 m)
100 ft (30.5 m)
125 ft (38.1 m)
150 ft (45.7 m)
Minimum AWG size of an extension cable for the mains connection
25 ft (7.6 m)
50 ft (15.2 m)
75 ft (22.9 m)
100 ft (30.5 m)
125 ft (38.1 m)
150 ft (45.7 m)
7
8
9
KEEP THESE INSTRUCTIONS CAREFULLY - This guide contains important
safety and operating instructions for these charger types (for model, see first
page of this document).
Do not expose the charger to rain or snow.
The use of accessories not sold or recommended by the charger manufac-
turer can lead to fire, electric shock or personal injury.
To reduce the risk of damage to plugs and cables, always unplug the charger
by pulling at the plug rather than the cable.
Use of an adapter is not allowed in Canada. If a grounding type receptacle is
not available, do not use this appliance until the proper outlet is installed by
a qualified electrician.
Only use an extension cable if it is absolutely necessary. The use of an incor-
rect extension cable can lead to fire and electric shock. If an extension cable
must be used, make sure that
-
the pins of the extension cable plug are of the same number, size and
shape as those of the charger plug
-
the extension cable is correctly wired and in good electrical condition
-
the cable size is large enough for the AC amperage of the charger, as in-
dicated above
2040 UL
AWG 12
AWG 12
AWG 12
AWG 12
AWG 10
AWG 10
4020 UL
AWG 12
AWG 12
AWG 12
AWG 12
AWG 10
AWG 10
Do not use the charger with a damaged cable or plug - replace the cable or
plug immediately.
Do not use the charger if it has been subjected to heavy impact, dropped or
otherwise damaged; hand it over to a qualified service technician.
Do not dismantle the charger; hand it over to a qualified service technician if
maintenance or repair is required. Incorrect reassembly can result in fire and
electric shock.
2050 UL
2070 UL
AWG 12
AWG 12
AWG 12
AWG 12
AWG 12
AWG 12
AWG 12
AWG 12
AWG 10
AWG 10
AWG 10
AWG 10
4035 UL
4045 UL
AWG 12
AWG 12
AWG 12
AWG 12
AWG 12
AWG 12
AWG 12
AWG 10
AWG 10
AWG 10
AWG 10
AWG 8
2120 UL
AWG 12
AWG 12
AWG 12
AWG 10
AWG 10
AWG 8
4060 UL
AWG 12
AWG 12
AWG 12
AWG 10
AWG 10
AWG 8