Overview of available options
Safety
The housing has to be partially opened to connect the options.
Danger of electric shock.
This may result in serious injuries or death.
Danger due to work that is not carried out properly.
This can result in severe personal injury and damage to property.
External start/
The external start/stop option prevents spark formation at the charging plug if it
stop
is disconnected during charging. Special contacts inside the charging plug re-
gister a disconnection. These contacts are leading in comparison to the main
contacts. An immediate charging stop is triggered. There is therefore no wear on
the main contacts and the level of safety against oxyhydrogen ignition is in-
creased.
Wall and floor
The robust wall and floor bracket with integrated cable holder ensures safe in-
bracket
stallation at the place of use. Detailed information and illustrations can be found
in the "Wall and floor bracket" section of the "General information" chapter.
LED strip
The LED strip serves as a status indicator and lights up in the corresponding col-
ors in the same way as the display elements of the control panel. An LED strip
including diffuser is installed in the gap between the front wall of the housing
and the upper part of the housing.
66
WARNING!
The housing must never be opened by anyone other than a service technician
trained by the manufacturer.
Before working with the housing open, the device must be disconnected from
the grid.
A suitable measuring device must be used to ensure that electrically charged
components (e.g., capacitors) are completely discharged.
With the aid of a clearly legible, understandable warning sign, ensure that
the device remains disconnected from the grid until all work has been com-
pleted.
WARNING!
All work involved with connecting optional components must only be carried
out by service technicians trained by the manufacturer.
If there are Installation Instructions or User Information for the optional
component concerned, then all warning notices and instructions therein
must be obeyed.
For all options with electrical connections, a safety inspection must be car-
ried out in accordance with the applicable national and international stand-
ards and guidelines after connection work has been carried out.
You can obtain more information about the safety inspection from the au-
thorized service body.