– between paths/obstacles that can be
travelled on (lower than 2 cm in height –
e.g. paths):
22 cm.
In corridors, the perimeter wire (1) must be
routed parallel and attached to the ground
with a sufficient number of fixing pins (2).
At the start and end of the corridor, funnel-
shaped entrance and exit areas must be
installed.
12.11 Guide loops for offset drive home
If offset drive home is activated, guide
loops must be provided
– if an external docking station has been
installed
or
– if there are corridors or confined areas
in the mowing area.
0478 131 9935 C - EN
Function:
When the robotic mower follows the
perimeter wire offset at a distance, it
crosses one of these guide loops during
the drive home. It then travels to the
perimeter wire and on to the docking
station.
Guide loops with an external docking
station:
To the right and left of the access to the
external docking station, two guide
loops (1) have to be installed at an angle of
90° to the perimeter wire.
Minimum clearance to access: 2 m
Guide loops with corridors:
To the right and left of the corridor access,
two guide loops (1) have to be installed at
an angle of 90° to the perimeter wire.
These must always be located in the part
of the mowing area that can only be
accessed via a corridor.
Minimum clearance to corridor access:
2 m
If several consecutive corridors are
installed, guide loops must be
installed in each of the relevant
mowing areas.
Installation of a guide loop:
Guide loops must not be installed in the
vicinity of corners.
Minimum clearance to corners: 2 m
139