Getting started with Analysis Vibration Sensor System
Make sure that the mounting base is seated properly on the measurement
location.
NOTE: Excessive mounting torque may damage the mounting adapter threads or the
machine housing. Too little torque may allow the mounting adapter to work loose
as proper coupling between the measurement location and the sensor may not be
achieved. Incorrect torque may cause measurement error.
Adhesive mounting
Use bonded mounting adapters to install the sensor on locations and machines
where screwing is not permissible.
Tools and accessories
 Power drill
 Drill bit (3.5 mm diameter)
 Depth gauge
 Degreasing solvent
 Adhesive (to mount sensor to adapter, and bond adapter to machine)
— recommended adhesives: LOCTITE 330; WEICON HD 300; UHU PLUS
SCHNELLFEST (UHU QUICKSET)
 Adhesive (to mount sensor to adapter) —
 Torque wrench
 Compressed air to clean mounting location
 Specially designed adapter wrench
 Grinding wheel