Installation
Electrical Installation
WARNING:
The installation of the electric fireplace must comply with the applicable Local and/or National Electrical Codes
and utility requirements.
Use the appropriate wire to meet local and national electrical codes for rated power consumption.
CAUTION: A dedicated, properly fused 15 Amp circuit is recommended, rated for the appropriate voltage (120 V,
240 V). A dedicated circuit will be required if, after installation, the circuit breaker trips or fuse blows on a regular
basis when the heater is operating. Additional appliances on the same circuit may exceed the current rating of
the circuit breaker.
120 V Hardwire Installation
!
NOTE: For OLF86-AM, when connected to 120 V, there will be no heat output, but heat functions will be
active on the controls with only fans operating.
1. Connect the black L1 wire from the unit to the live wire from the power supply with a wire connector.
2. Connect the white N wire from the unit to the neutral wire from the power supply with a wire connector.
3. Connect the green G wire from the unit to the ground wire from the power supply with a wire connector or
attach the grounding wire to the cover with the provided grounding screw, by placing the wire in between
screw and lock washer and tighten.
4. Ensure all wire connections are tight.
14
Figure 10
White - Neutral
Black - L1
Red - L2
Green - Ground
White - Neutral
Black - L1
Red - L2
Green - Ground
White - Neutral
120 V
Black - L
POWER
SUPPLY
(BREAKER
PANEL)
Green - Ground
White - Neutral
240 V
POWER
Black - L
SUPPLY
(BREAKER
RED – L2
PANEL)
Green - Ground
www.dimplex.com