Télécharger Imprimer la page

Dimplex Optimyst OLF46-AM Guide D'installation Et D'utilisation page 12

Publicité

Les langues disponibles

Les langues disponibles

Installation
Installation Instructions
!
NOTE: Two people are recommended for installation.
1. Follow the instructions in the section Preparing the
Firebox for Installation (page 10) before beginning.
2. Prepare a wall with a framed opening, following the
dimensions in the Framing section (page 11).
CAUTION: Ensure there is an air inlet with a path for
air flow to reach the underside of the unit.
3. Place the firebox into the framed opening. Ensure the
unit is level. A bubble level is included in the hardware
kit provided.
4. Secure the firebox to the frame using the previously
removed mounting brackets. The unit must be
secured to the frame with the mounting brackets.
!
NOTE: To avoid bulging of the finished surface, notch
the framing to allow the mounting brackets to be flush
with the framing. (Figure 7)
5. Connect the unit to the water supply, following the
instructions in the section Water Supply Connection
(page 13).
6. Locate the connector plate in the top right back
corner of the unit. Remove the connector plate by
removing the 2 securing screws. (Figure 8)
7. Install a cable connector (not included), suitable for
installing in a
/
" (22 mm) hole, to the plate and feed
7
8
the supply cable through the cable connector.
8. Complete the wiring according to instructions in the
Electrical Installation section (pages 14–15). Reinstall
the connector plate after completing wiring.
9. Finish surrounding wall up to the trim if a permanent
installation is desired. A removable trim can be used
instead to cover the framing opening to allow the
fireplace to be removed without damaging the finished
wall.
CAUTION: Ensure air inlets are present in final
installation (see Fresh Air Inlets, page 10).
!
NOTE: It is recommended that all drywall installation
and finishing be completed after unit is fully installed,
inspected, and operational.
10. Finish the installation using the finishing materials of
your choice.
11. Place the media as desired and install the front glass.
12
Figure 7
Figure 8
Mounting bracket
Notch framing for
flush installation.
Connector plate
www.dimplex.com

Publicité

loading

Ce manuel est également adapté pour:

Optimyst olf66-amOptimyst olf86-am