Maintenance
Remote Control Battery Replacement
To replace the batteries:
1. Remove battery cover of the remote control using a Philips screwdriver.
2. Correctly install two 3 Volt (CR2032 or similar) battery in the battery holder with
the + side facing up.
3. Secure the battery cover using the previously removed screw.
Batteries must be recycled or disposed of properly. Check with your Local
Authority or Retailer for recycling advice in your area.
Cleaning
WARNING: Disconnect power and allow heater to cool before attempting any
maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons.
CAUTION: The heater should not be operated with an accumulation of dust or dirt on or in the unit, as this can
cause a build-up of heat and eventual damage. For this reason the heater must be inspected regularly, depending
upon conditions and at a minimum yearly intervals.
Fireplace Surface Cleaning
Use only a damp cloth to clean the glass and painted surfaces of the fireplace. The inner side of the glass may
occasionally get cloudy and require cleaning. Do not use abrasive cleaners.
Component Cleaning
It is required that the top cover, sump, water
bottle (if used), and transducers are cleaned
with soap and water on a regular basis, at a
minimum once per month. More frequent
cleaning may be required depending on water
quality.
CAUTION: Do not put plastic components in
the dishwasher.
The air filters can be removed and gently rinsed
with water to clean and dried on a towel before
reinstalling. Reinstall the filter so that the coarse
black side of the filter is facing the back of the
unit.
Transducer Replacement
After prolonged use, the ability for the unit to produce mist may become reduced. If cleaning does not improve the
performance of the flame effect, replacement of the transducer may be required. This unit comes with replacement
transducers. Additional transducers may be purchased at www.dimplex.com/replacement_parts (9601210100RP).
! NOTE: To remove the transducer, release the retaining tab in the sump and remove transducer.
Servicing
Except for installation and cleaning described in this manual, an authorized service representative should perform
any other servicing.
Figure 22
Top Cover
Sump
Figure 21
Air Filter
Transducer
Minimum and Maximum
Water Level Indicators
23