Installation
Heater Hardware Disconnect
The fireplace heater can be permanently disabled by removing the electronic jumper on the main control board.
Heater hardware disconnect will permanently disable the heater and fan function. Follow these instructions ONLY
when an installation without heat is required. Temporary disabling of the heater can be achieved through the hidden
touch controls. See "Heat Disable" in Operation section (page 20) for instructions.
The recirculating fan and the element in the flame module will not be disabled.
To disconnect the heater and fan permanently:
1. Remove the 4 screws that secure the right-side upper LED lights and disconnect the wire.
2. Remove the 5 screws that secure the right-side upper panel. Carefully lower the upper panel, which is held by
hinges to the housing.
3. Locate the main control board. The heater hardware disconnect jumper location is labeled "J2". (Figure 13)
4. Remove the heater hardware disconnect jumper.
5. Secure the upper panel back in its original position.
6. Reconnect the wire for the upper LED lights, and secure in place.
Figure 13
16
Heater Hardware
Disconnect Jumper