Renson Camargue Skye Notice De Montage page 55

Table des Matières

Publicité

15. Connecting cabling
(continued 2)
• Provide the Camargue Skye transfo with
power 230 V. E
• As soon as the control get power the 4 red
LED lamps on the control panel light up one
after the other. F
• There are also 1 orange and green LED
lamp lit on the control panel for each
connected ethernet cable. Check this
because this indicates that the cable is
connected correctly and there is a network
connection. G
Green LED: cable connnected.
Orange LED: data is sending.
The motor will not move yet.
• Connect the 1st MAIN-control to the
Camargue Skye-control with the Renson
Networkcable. H
• Provide the 1st MAIN transfo with power
230 V. I
• If there is also a second MAIN-control,
connect these to the first MAIN-control with
the Renson Networkcable. J
• Provide the second MAIN transfo with
power 230 V. K
• You can connect the optional Rain sensor
on the Camargue Skye-control or on the
MAIN-control. L
1 > GRN
3 > Rain_A
4 > Rain_B
2 > +24V
Remark: 1 rain sensor is enough for a
coupled Camargue Skye with several roof
parts.
• Connect the LEDs with the cables which are
already provided on the MAIN-control. M
LED (white)
LED (white)
LED (RGB)
LED (RGB)
230 V
Netzteil/Transfo
MAIN-Steuerung 2
MAIN control 2
G
LED
M
K
F
GND
Rain_B
Rain_A
+24V
Or/Wh
Or
IN
Gr/Wh
Gr
Or/Wh
Or
Gr/Wh
Gr
Shield
IN
Or/Wh
Or
Gr/Wh
Gr
J
Or/Wh
Or
Gr/Wh
Gr
Shield
55

Publicité

Table des Matières
loading

Table des Matières