Any error messages that have been issued are registered here.
PROBLEM
No blades detected by the tilt end sensors.
The motor temperature was too high.
Malfunction of both motor temperature sensors.
It is no longer possible to check the temperature.
One of the motors reached its current limit value.
This may be caused by an obstacle or by wind resistance.
The end sensors are not detected before they go to tilt mode.
My outdoor
Weather settings
My
application
Installer settings
My
network
PASSWORD REQUIRED
Error log
NO ERRORS
SOLUTION
1. Check that the blades are present.
2. Check that the motor axle is connected.
3. Unplug the plug from the socket and plug it in again after 30 seconds.
4. If the error persists after restarting, check the wiring or replace the motherboard.
1. Allow the motor to cool down for 10 minutes and try again.
2. If the error also persists in cold temperatures, check the wiring or replace the motherboard.
1. Check the wiring.
2. Replace the temperature sensors.
3. If the error persists after restarting, replace the motherboard.
1. Check whether an obstacle is blocking the device.
2. Try the last command again.
3. Check the wiring and the motors.
4. Replace the defective motor.
5. If the error persists after restarting, replace the motherboard.
1. Check the wiring and replace the defective end sensors.
2. Unplug the plug from the socket and plug it in again after 30 seconds.
3. If the error also persists in cold temperatures, check the wiring or replace the motherboard.